Diode test With Digital Multimeter
- Select the mode in accordance with resistant diode (digital multimeter if there is no option can select the metering mode diode resistance / Ohm) by turning the switch digital meters
- Diode-called normal or diode good condition when the small resistance value when the probe red wire is connected to the leg diode anode (+) and black wire probe connected by foot cathode (-).
- Also said to be good if the big resistance approaching infinity when mounting the probe on the diode was reversed.
- Diode on short condition when the value of resistance of 0 ohms when measured in accordance with the direction llistrik current direction (forward / step 2) and the opposite position (reverse).
- Diode open or broken condition when the value of resistance approaches infinity when measured in the direction of the electric current (forward / step 2) and the opposite position (reverse).Diode test With Analog Multimeter
- Select the resistance measurement mode (OHM) with resistance levels (range x 100) by turning the switch select analog multi-meter.
- Diode considered normal if the resistance value is small (multimeter needle close to the value 0 Ohm) when the probe red wire is connected to the diode anode (+) and black wire probe connected to the cathode (-).
- And also the diode is said to be good if a large resistance (multimeter needle does not move) when mounting the probe on the diode is reversed.
- Diode on short condition when the value of resistance of 0 ohms when measured in accordance with the direction llistrik current direction (forward / step 2) and the opposite position (reverse).
- Diode open or broken condition when the value of resistance approaches infinity when measured in the direction of the electric current (forward / step 2) and the opposite position (reverse).
0 Response to "Test the Diode With Multimeter"